{"document":{"acknowledgments":[{"organization":"CERT@VDE","summary":"coordination","urls":["https://certvde.com"]}],"category":"csaf_security_advisory","csaf_version":"2.0","distribution":{"tlp":{"label":"WHITE","url":"https://www.first.org/tlp/"}},"lang":"en-GB","notes":[{"category":"summary","text":"Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are prone to multiple vulnerabilities which could lead up to a full compromise of the FDS101 device.","title":"Summary"},{"category":"description","text":"Please consult the CVE Entries above.","title":"Impact"},{"category":"description","text":"Security-related application conditions SecRAC\nThe railway operator must ensure that only authorised personnel or people in the company of authorised personnel have access to the Frauscher Diagnostic System FDS101.\nThe recommendation is to connect the Frauscher Diagnostic System FDS101 to a network of category 2.\nIf the Frauscher Diagnostic System FDS101 is connected to a network of category 3 (according to EN 50159:2010), then additional protective measures must be added.","title":"Mitigation"},{"category":"description","text":"Update to FDS102 v2.10.1","title":"Remediation"}],"publisher":{"category":"vendor","contact_details":"psirt@frauscher.com","name":"Frauscher Sensortechnik GmbH","namespace":"https://www.frauscher.com"},"references":[{"category":"self","summary":"VDE-2023-038: Frauscher: Multiple Vulnerabilities in FDS101 - HTML","url":"https://certvde.com/en/advisories/VDE-2023-038/"},{"category":"self","summary":"VDE-2023-038: Frauscher: Multiple Vulnerabilities in FDS101 - CSAF","url":"https://frauscher.csaf-tp.certvde.com/.well-known/csaf/white/2023/vde-2023-038.json"},{"category":"external","summary":"Vendor PSIRT","url":"https://www.frauscher.com"},{"category":"external","summary":"CERT@VDE Security Advisories for Frauscher Sensortechnik GmbH","url":"https://certvde.com/en/advisories/vendor/frauscher/"}],"title":"Frauscher: Multiple Vulnerabilities in FDS101","tracking":{"aliases":["VDE-2023-038"],"current_release_date":"2023-09-21T06:00:00.000Z","generator":{"date":"2025-04-30T09:30:14.935Z","engine":{"name":"Secvisogram","version":"2.5.24"}},"id":"VDE-2023-038","initial_release_date":"2023-09-21T06:00:00.000Z","revision_history":[{"date":"2023-09-21T06:00:00.000Z","number":"1","summary":"Initial revision."}],"status":"final","version":"1"}},"product_tree":{"branches":[{"branches":[{"branches":[{"category":"product_name","name":"FDS101 for FAdC/FAdCi","product":{"name":"FDS101 for FAdC/FAdCi","product_id":"CSAFPID-11001"}}],"category":"product_family","name":"Hardware"},{"branches":[{"category":"product_version_range","name":"<=1.4.24","product":{"name":"Firmware <=1.4.24","product_id":"CSAFPID-21001"}},{"category":"product_version","name":"v2.10.1","product":{"name":"Firmware v2.10.1","product_id":"CSAFPID-22001"}}],"category":"product_family","name":"Firmware"}],"category":"vendor","name":"Frauscher"}],"relationships":[{"category":"installed_on","full_product_name":{"name":"Firmware <=1.4.24 installed on FDS101 for FAdC/FAdCi","product_id":"CSAFPID-31001"},"product_reference":"CSAFPID-21001","relates_to_product_reference":"CSAFPID-11001"},{"category":"installed_on","full_product_name":{"name":"Firmware v2.10.1 installed on FDS101 for FAdC/FAdCi","product_id":"CSAFPID-32001"},"product_reference":"CSAFPID-22001","relates_to_product_reference":"CSAFPID-11001"}]},"vulnerabilities":[{"cve":"CVE-2023-4292","cwe":{"id":"CWE-89","name":"Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')"},"notes":[{"category":"description","text":"Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a SQL injection vulnerability via manipulated parameters of the web interface without authentication. The database contains limited, non-critical log information.\n\n\n\n","title":"Vulnerability Description"}],"product_status":{"fixed":["CSAFPID-32001"],"known_affected":["CSAFPID-31001"]},"remediations":[{"category":"mitigation","details":"Security-related application conditions SecRAC\nThe railway operator must ensure that only authorised personnel or people in the company of authorised personnel have access to the Frauscher Diagnostic System FDS101.\nThe recommendation is to connect the Frauscher Diagnostic System FDS101 to a network of category 2.\nIf the Frauscher Diagnostic System FDS101 is connected to a network of category 3 (according to EN 50159:2010), then additional protective measures must be added.","product_ids":["CSAFPID-31001"]},{"category":"vendor_fix","details":"Update to FDS102 v2.10.1","product_ids":["CSAFPID-31001"]}],"scores":[{"cvss_v3":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":5.3,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","environmentalScore":5.3,"environmentalSeverity":"MEDIUM","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","temporalScore":5.3,"temporalSeverity":"MEDIUM","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"products":["CSAFPID-31001"]}],"title":"CVE-2023-4292"},{"cve":"CVE-2023-4291","cwe":{"id":"CWE-94","name":"Improper Control of Generation of Code ('Code Injection')"},"notes":[{"category":"description","text":"Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a remote code execution (RCE) vulnerability via manipulated parameters of the web interface without authentication. This could lead to a full compromise of the FDS101 device.\n\n\n","title":"Vulnerability Description"}],"product_status":{"fixed":["CSAFPID-32001"],"known_affected":["CSAFPID-31001"]},"remediations":[{"category":"mitigation","details":"Security-related application conditions SecRAC\nThe railway operator must ensure that only authorised personnel or people in the company of authorised personnel have access to the Frauscher Diagnostic System FDS101.\nThe recommendation is to connect the Frauscher Diagnostic System FDS101 to a network of category 2.\nIf the Frauscher Diagnostic System FDS101 is connected to a network of category 3 (according to EN 50159:2010), then additional protective measures must be added.","product_ids":["CSAFPID-31001"]},{"category":"vendor_fix","details":"Update to FDS102 v2.10.1","product_ids":["CSAFPID-31001"]}],"scores":[{"cvss_v3":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","environmentalScore":9.8,"environmentalSeverity":"CRITICAL","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","temporalScore":9.8,"temporalSeverity":"CRITICAL","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"products":["CSAFPID-31001"]}],"title":"CVE-2023-4291"},{"cve":"CVE-2023-4152","cwe":{"id":"CWE-22","name":"Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')"},"notes":[{"category":"description","text":"Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS101 device.\n","title":"Vulnerability Description"}],"product_status":{"fixed":["CSAFPID-32001"],"known_affected":["CSAFPID-31001"]},"remediations":[{"category":"mitigation","details":"Security-related application conditions SecRAC\nThe railway operator must ensure that only authorised personnel or people in the company of authorised personnel have access to the Frauscher Diagnostic System FDS101.\nThe recommendation is to connect the Frauscher Diagnostic System FDS101 to a network of category 2.\nIf the Frauscher Diagnostic System FDS101 is connected to a network of category 3 (according to EN 50159:2010), then additional protective measures must be added.","product_ids":["CSAFPID-31001"]},{"category":"vendor_fix","details":"Update to FDS102 v2.10.1","product_ids":["CSAFPID-31001"]}],"scores":[{"cvss_v3":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","environmentalScore":7.5,"environmentalSeverity":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","temporalScore":7.5,"temporalSeverity":"HIGH","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"products":["CSAFPID-31001"]}],"title":"CVE-2023-4152"}]}