  "document": {
    "acknowledgments": [
      {
        "organization": "CERT@VDE",
        "summary": "coordination",
        "urls": [
          "https://certvde.com"
        ]
      }
    ],
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "tlp": {
        "label": "WHITE",
        "url": "https://www.first.org/tlp/"
      }
    },
    "lang": "en-GB",
    "notes": [
      {
        "category": "summary",
        "text": "Frauscher Sensortechnik GmbH FDS102 for FAdC/FAdCi v2.10.1 is vulnerable to a remote code execution (RCE) vulnerability via manipulated parameters of the web interface by using an authenticated session cookie.",
        "title": "Summary"
      },
      {
        "category": "description",
        "text": "This vulnerability may lead to a full compromise of the FDS102 device.",
        "title": "Impact"
      },
      {
        "category": "description",
        "text": "Security-related application conditions SecRAC\n\nThe railway operator must ensure that only authorised personnel or people in the company of authorised personnel have access to the Frauscher Diagnostic System FDS102.\n\nThe recommendation is to connect the Frauscher Diagnostic System FDS102 to a network of category 2. If the Frauscher Diagnostic System FDS102 is connected to a network of category 3 (according to EN 50159:2010), then additional protective measures must be added.",
        "title": "Mitigation"
      },
      {
        "category": "description",
        "text": "Update to FDS102 v2.10.2",
        "title": "Remediation"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "psirt@frauscher.com",
      "name": "Frauscher Sensortechnik GmbH",
      "namespace": "https://www.frauscher.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "VDE-2023-049: Frauscher: FDS102 for FAdC/FAdCi remote code execution vulnerability - HTML",
        "url": "https://certvde.com/en/advisories/VDE-2023-049/"
      },
      {
        "category": "self",
        "summary": "VDE-2023-049: Frauscher: FDS102 for FAdC/FAdCi remote code execution vulnerability - CSAF",
        "url": "https://frauscher.csaf-tp.certvde.com/.well-known/csaf/white/2023/vde-2023-049.json"
      },
      {
        "category": "external",
        "summary": "Vendor PSIRT",
        "url": "https://www.frauscher.com"
      },
      {
        "category": "external",
        "summary": "CERT@VDE Security Advisories for Frauscher Sensortechnik GmbH",
        "url": "https://certvde.com/en/advisories/vendor/frauscher/"
      }
    ],
    "title": "Frauscher: FDS102 for FAdC/FAdCi remote code execution vulnerability",
    "tracking": {
      "aliases": [
        "VDE-2023-049"
      ],
      "current_release_date": "2023-12-11T07:00:00.000Z",
      "generator": {
        "date": "2025-05-05T08:24:30.960Z",
        "engine": {
          "name": "Secvisogram",
          "version": "2.5.24"
        }
      },
      "id": "VDE-2023-049",
      "initial_release_date": "2023-12-11T07:00:00.000Z",
      "revision_history": [
        {
          "date": "2023-12-11T07:00:00.000Z",
          "number": "1",
          "summary": "Initial revision."
        }
      ],
      "status": "final",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_name",
                "name": "FDS102 for FAdC/FAdCi",
                "product": {
                  "name": "FDS102 for FAdC/FAdCi",
                  "product_id": "CSAFPID-11001"
                }
              }
            ],
            "category": "product_family",
            "name": "Hardware"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "2.10.0<=2.10.1",
                "product": {
                  "name": "Firmware 2.10.0<=2.10.1",
                  "product_id": "CSAFPID-21001"
                }
              },
              {
                "category": "product_version",
                "name": "v2.10.2",
                "product": {
                  "name": "Firmware v2.10.2",
                  "product_id": "CSAFPID-22001"
                }
              }
            ],
            "category": "product_family",
            "name": "Firmware"
          }
        ],
        "category": "vendor",
        "name": "Frauscher"
      }
    ],
    "relationships": [
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "Firmware 2.10.0<=2.10.1 installed on FDS102 for FAdC/FAdCi",
          "product_id": "CSAFPID-31001"
        },
        "product_reference": "CSAFPID-21001",
        "relates_to_product_reference": "CSAFPID-11001"
      },
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "Firmware v2.10.2 installed on FDS102 for FAdC/FAdCi",
          "product_id": "CSAFPID-32001"
        },
        "product_reference": "CSAFPID-22001",
        "relates_to_product_reference": "CSAFPID-11001"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2023-5500",
      "cwe": {
        "id": "CWE-94",
        "name": "Improper Control of Generation of Code ('Code Injection')"
      },
      "notes": [
        {
          "category": "description",
          "text": "This vulnerability allows an remote attacker with low privileges to misuse Improper Control of Generation of Code ('Code Injection') to gain full control of the affected device.",
          "title": "Vulnerability Description"
        }
      ],
      "product_status": {
        "fixed": [
          "CSAFPID-32001"
        ],
        "known_affected": [
          "CSAFPID-31001"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Security-related application conditions SecRAC\n\nThe railway operator must ensure that only authorised personnel or people in the company of authorised personnel have access to the Frauscher Diagnostic System FDS102.\n\nThe recommendation is to connect the Frauscher Diagnostic System FDS102 to a network of category 2. If the Frauscher Diagnostic System FDS102 is connected to a network of category 3 (according to EN 50159:2010), then additional protective measures must be added.",
          "product_ids": [
            "CSAFPID-31001"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to FDS102 v2.10.2",
          "product_ids": [
            "CSAFPID-31001"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "environmentalScore": 8.8,
            "environmentalSeverity": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "temporalScore": 8.8,
            "temporalSeverity": "HIGH",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-31001"
          ]
        }
      ],
      "title": "CVE-2023-5500"
    }
  ]
}