vde-2021-018

HIGH CVSS 8.6 csaf_pepperlfuchsse
Description

Critical vulnerability has been discovered in the utilized components rcX, mbedTLS, PROFINET IO Device and EtherNet/IP Core by Hilscher Gesellschaft für Systemautomation mbH. The impact of the vulnerabilities on the affected device is that it can result in: * Denial of Service (DoS) * Remote Code Execution (RCE) * Code Exposure **Note:** ICE1-8IOL-S2-G60L-V1D (70103603) is not affected by CVE-2021-20986

Timeline
Published
2021-05-12 08:57 UTC
Last Modified
2021-05-12
CVSS Details

CVSS details not available.

Affected Products

No product information available.

Weaknesses (CWE)
References

No references available.

Linked Vulnerabilities

No linked vulnerabilities found.

{
  "document": {
    "acknowledgments": [
      {
        "organization": "CERT@VDE",
        "summary": "coordination",
        "urls": [
          "https://certvde.com"
        ]
      },
      {
        "organization": "Hilscher Gesellschaft für Systemautomation mbH",
        "summary": "reporting."
      }
    ],
    "aggregate_severity": {
      "namespace": "https://www.first.org/cvss/v3.1/specification-document#Qualitative-Severity-Rating-Scale",
      "text": "High"
    },
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "tlp": {
        "label": "WHITE",
        "url": "https://www.first.org/tlp/"
      }
    },
    "lang": "en-GB",
    "notes": [
      {
        "category": "summary",
        "text": "Critical vulnerability has been discovered in the utilized components rcX, mbedTLS, PROFINET IO Device and EtherNet/IP Core by Hilscher Gesellschaft für Systemautomation mbH.\nThe impact of the vulnerabilities on the affected device is that it can result in:\n* Denial of Service (DoS)\n* Remote Code Execution (RCE)\n* Code Exposure\n\n**Note:**\nICE1-8IOL-S2-G60L-V1D (70103603) is not affected by CVE-2021-20986",
        "title": "Summary"
      },
      {
        "category": "description",
        "text": "Pepperl+Fuchs analyzed and identified affected devices.\nRemote attackers may exploit the vulnerability sending specially crafted packages that may result in a denial-of-service condition or code execution.",
        "title": "Impact"
      },
      {
        "category": "description",
        "text": "An external protective measure is required. Minimize network exposure for affected products and ensure that they are not accessible via the Internet.\nIsolate affected products from the corporate network. If remote access is required, use secure methods such as virtual private networks (VPNs).",
        "title": "Mitigation"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "cert@pepperl-fuchs.com",
      "name": "Pepperl+Fuchs SE",
      "namespace": "https://www.pepperl-fuchs.com"
    },
    "references": [
      {
        "category": "external",
        "summary": "Pepperl+Fuchs advisory overview at CERT@VDE",
        "url": "https://certvde.com/de/advisories/vendor/pepperl+fuchs/"
      },
      {
        "category": "self",
        "summary": "VDE-2021-018: Pepperl+Fuchs: Multiple vulnerabilites in ICE1 Ethernet IO Modules - HTML",
        "url": "https://certvde.com/en/advisories/VDE-2021-018"
      },
      {
        "category": "self",
        "summary": "VDE-2021-018: Pepperl+Fuchs: Multiple vulnerabilites in ICE1 Ethernet IO Modules - CSAF",
        "url": "https://pepperl-fuchs.csaf-tp.certvde.com/.well-known/csaf/white/2021/vde-2021-018.json"
      }
    ],
    "source_lang": "en",
    "title": "Pepperl+Fuchs: Multiple vulnerabilites in ICE1 Ethernet IO Modules",
    "tracking": {
      "aliases": [
        "VDE-2021-018"
      ],
      "current_release_date": "2021-05-12T08:57:00.000Z",
      "generator": {
        "date": "2024-12-06T08:39:04.675Z",
        "engine": {
          "name": "Secvisogram",
          "version": "2.5.15"
        }
      },
      "id": "VDE-2021-018",
      "initial_release_date": "2021-05-12T08:57:00.000Z",
      "revision_history": [
        {
          "date": "2021-05-12T08:57:00.000Z",
          "number": "1",
          "summary": "Initial revision."
        }
      ],
      "status": "final",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "branches": [
                  {
                    "category": "product_version_range",
                    "name": "<= F10017",
                    "product": {
                      "name": "Hardware ICE1-16DI-G60L-V1D <= F10017",
                      "product_id": "CSAFPID-11001"
                    }
                  }
                ],
                "category": "product_name",
                "name": "ICE1-16DI-G60L-V1D"
              },
              {
                "branches": [
                  {
                    "category": "product_version_range",
                    "name": "<= F10017",
                    "product": {
                      "name": "Hardware ICE1-16DIO-G60L-C1-V1D <= F10017",
                      "product_id": "CSAFPID-11002"
                    }
                  }
                ],
                "category": "product_name",
                "name": "ICE1-16DIO-G60L-C1-V1D"
              },
              {
                "branches": [
                  {
                    "category": "product_version_range",
                    "name": "<= F10017",
                    "product": {
                      "name": "Hardware ICE1-16DIO-G60L-V1D <= F10017",
                      "product_id": "CSAFPID-11003"
                    }
                  }
                ],
                "category": "product_name",
                "name": "ICE1-16DIO-G60L-V1D"
              },
              {
                "branches": [
                  {
                    "category": "product_version_range",
                    "name": "<= F10017",
                    "product": {
                      "name": "Hardware ICE1-8DI8DO-G60L-C1-V1D <= F10017",
                      "product_id": "CSAFPID-11004"
                    }
                  }
                ],
                "category": "product_name",
                "name": "ICE1-8DI8DO-G60L-C1-V1D"
              },
              {
                "branches": [
                  {
                    "category": "product_version_range",
                    "name": "<= F10017",
                    "product": {
                      "name": "Hardware ICE1-8DI8DO-G60L-V1D <= F10017",
                      "product_id": "CSAFPID-11005"
                    }
                  }
                ],
                "category": "product_name",
                "name": "ICE1-8DI8DO-G60L-V1D"
              },
              {
                "branches": [
                  {
                    "category": "product_version_range",
                    "name": "<= F10017",
                    "product": {
                      "name": "Hardware ICE1-8IOL-G30L-V1D <= F10017",
                      "product_id": "CSAFPID-11006"
                    }
                  }
                ],
                "category": "product_name",
                "name": "ICE1-8IOL-G30L-V1D"
              },
              {
                "branches": [
                  {
                    "category": "product_version_range",
                    "name": "<= F10017",
                    "product": {
                      "name": "Hardware ICE1-8IOL-G60L-V1D <= F10017",
                      "product_id": "CSAFPID-11007"
                    }
                  }
                ],
                "category": "product_name",
                "name": "ICE1-8IOL-G60L-V1D"
              },
              {
                "branches": [
                  {
                    "category": "product_version_range",
                    "name": "<= F10017",
                    "product": {
                      "name": "Hardware ICE1-8IOL-S2-G60L-V1D <= F10017",
                      "product_id": "CSAFPID-11008"
                    }
                  }
                ],
                "category": "product_name",
                "name": "ICE1-8IOL-S2-G60L-V1D"
              }
            ],
            "category": "product_family",
            "name": "Hardware"
          }
        ],
        "category": "vendor",
        "name": "Pepperl+Fuchs"
      }
    ],
    "product_groups": [
      {
        "group_id": "CSAFGID-0001",
        "product_ids": [
          "CSAFPID-11001",
          "CSAFPID-11002",
          "CSAFPID-11003",
          "CSAFPID-11004",
          "CSAFPID-11005",
          "CSAFPID-11006",
          "CSAFPID-11007",
          "CSAFPID-11008"
        ],
        "summary": "Affected Products."
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2021-20987",
      "cwe": {
        "id": "CWE-787",
        "name": "Out-of-bounds Write"
      },
      "notes": [
        {
          "audience": "all",
          "category": "description",
          "text": "A denial of service and memory corruption vulnerability was found in Hilscher EtherNet/IP Core V2 prior to V2.13.0.21that may lead to code injection through network or make devices crash without recovery.",
          "title": "Vulnerability Description"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-11001",
          "CSAFPID-11002",
          "CSAFPID-11003",
          "CSAFPID-11004",
          "CSAFPID-11005",
          "CSAFPID-11006",
          "CSAFPID-11007",
          "CSAFPID-11008"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "An external protective measure is required.\n\nMinimize network exposure for affected products and ensure that they are not accessible via the Internet.\nIsolate affected products from the corporate network.\nIf remote access is required, use secure methods such as virtual private networks (VPNs).",
          "group_ids": [
            "CSAFGID-0001"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "environmentalScore": 8.6,
            "environmentalSeverity": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "temporalScore": 8.6,
            "temporalSeverity": "HIGH",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-11001",
            "CSAFPID-11002",
            "CSAFPID-11003",
            "CSAFPID-11004",
            "CSAFPID-11005",
            "CSAFPID-11006",
            "CSAFPID-11007",
            "CSAFPID-11008"
          ]
        }
      ],
      "title": "CVE-2021-20987"
    },
    {
      "cve": "CVE-2021-20988",
      "cwe": {
        "id": "CWE-119",
        "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
      },
      "notes": [
        {
          "audience": "all",
          "category": "description",
          "text": "In Hilscher rcX RTOS versions prios to V2.1.14.1 the actual UDP packet length is not verified against the length indicated by the packet. This may lead to a denial of service of the affected device.",
          "title": "Vulnerability Description"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-11001",
          "CSAFPID-11002",
          "CSAFPID-11003",
          "CSAFPID-11004",
          "CSAFPID-11005",
          "CSAFPID-11006",
          "CSAFPID-11007",
          "CSAFPID-11008"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "An external protective measure is required.\n\nMinimize network exposure for affected products and ensure that they are not accessible via the Internet.\nIsolate affected products from the corporate network.\nIf remote access is required, use secure methods such as virtual private networks (VPNs).",
          "group_ids": [
            "CSAFGID-0001"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "environmentalScore": 7.5,
            "environmentalSeverity": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "temporalScore": 7.5,
            "temporalSeverity": "HIGH",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-11001",
            "CSAFPID-11002",
            "CSAFPID-11003",
            "CSAFPID-11004",
            "CSAFPID-11005",
            "CSAFPID-11006",
            "CSAFPID-11007",
            "CSAFPID-11008"
          ]
        }
      ],
      "title": "CVE-2021-20988"
    },
    {
      "cve": "CVE-2021-20986",
      "cwe": {
        "id": "CWE-787",
        "name": "Out-of-bounds Write"
      },
      "notes": [
        {
          "audience": "all",
          "category": "description",
          "text": "A Denial of Service vulnerability was found in Hilscher PROFINET IO Device V3 in versions prior to V3.14.0.7. This may lead to unexpected loss of cyclic communication or interruption of acyclic communication.",
          "title": "Vulnerability Description"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-11001",
          "CSAFPID-11002",
          "CSAFPID-11003",
          "CSAFPID-11004",
          "CSAFPID-11005",
          "CSAFPID-11006",
          "CSAFPID-11007",
          "CSAFPID-11008"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "An external protective measure is required.\n\nMinimize network exposure for affected products and ensure that they are not accessible via the Internet.\nIsolate affected products from the corporate network.\nIf remote access is required, use secure methods such as virtual private networks (VPNs).",
          "group_ids": [
            "CSAFGID-0001"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "environmentalScore": 7.5,
            "environmentalSeverity": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "temporalScore": 7.5,
            "temporalSeverity": "HIGH",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-11001",
            "CSAFPID-11002",
            "CSAFPID-11003",
            "CSAFPID-11004",
            "CSAFPID-11005",
            "CSAFPID-11006",
            "CSAFPID-11007",
            "CSAFPID-11008"
          ]
        }
      ],
      "title": "CVE-2021-20986"
    },
    {
      "cve": "CVE-2019-18222",
      "cwe": {
        "id": "CWE-203",
        "name": "Observable Discrepancy"
      },
      "notes": [
        {
          "audience": "all",
          "category": "description",
          "text": "The ECDSA signature implementation in ecdsa.c in Arm Mbed Crypto 2.1 and Mbed TLS through 2.19.1 does not reduce the blinded scalar before computing the inverse, which allows a local attacker to recover the private key via side-channel attacks.",
          "title": "Vulnerability Description"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-11001",
          "CSAFPID-11002",
          "CSAFPID-11003",
          "CSAFPID-11004",
          "CSAFPID-11005",
          "CSAFPID-11006",
          "CSAFPID-11007",
          "CSAFPID-11008"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "An external protective measure is required.\n\nMinimize network exposure for affected products and ensure that they are not accessible via the Internet.\nIsolate affected products from the corporate network.\nIf remote access is required, use secure methods such as virtual private networks (VPNs).",
          "group_ids": [
            "CSAFGID-0001"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "environmentalScore": 4.7,
            "environmentalSeverity": "MEDIUM",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "temporalScore": 4.7,
            "temporalSeverity": "MEDIUM",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-11001",
            "CSAFPID-11002",
            "CSAFPID-11003",
            "CSAFPID-11004",
            "CSAFPID-11005",
            "CSAFPID-11006",
            "CSAFPID-11007",
            "CSAFPID-11008"
          ]
        }
      ],
      "title": "CVE-2019-18222"
    }
  ]
}
View JSON API Download JSON