vde-2023-032

CRITICAL CVSS 9.8 csaf_weidmuellerinterfacegmbhcokg
Description

Multiple Weidmueller products are affected by recent WIBU vulnerability.

Timeline
Published
2023-11-09 07:42 UTC
Last Modified
2025-05-22
CVSS Details

CVSS details not available.

Affected Products

No product information available.

Weaknesses (CWE)
References

No references available.

Linked Vulnerabilities

No linked vulnerabilities found.

{
  "document": {
    "acknowledgments": [
      {
        "organization": "CERT@VDE",
        "summary": "coordination",
        "urls": [
          "https://certvde.com"
        ]
      }
    ],
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "tlp": {
        "label": "WHITE",
        "url": "https://www.first.org/tlp/"
      }
    },
    "lang": "en-GB",
    "notes": [
      {
        "category": "summary",
        "text": "Multiple Weidmueller products are affected by recent WIBU vulnerability.",
        "title": "Summary"
      },
      {
        "category": "description",
        "text": "An attacker exploiting the vulnerability in WIBU CodeMeter Runtime in server mode could gain full access to the affected server via network access without any user interaction.\nExploiting the vulnerability in WIBU CodeMeter Runtime in non-networked workstation mode could lead to a privilege elevation and full admin access on this workstation.",
        "title": "Impact"
      },
      {
        "category": "description",
        "text": "u-create studio:\nDisabling the network server function within CodeMeter would mitigate the vulnerability. To disable this function\nplease refer to the following steps:\n\n1. Navigate to the CodeMeter WebAdmin Website\n2. Select option Settings > Server > Server access\n3. Choose option 'deactivate' in section 'network server'\n4. Click 'Apply' button on the bottom of the website",
        "title": "Mitigation"
      },
      {
        "category": "description",
        "text": "For the affected **u-control web Controllers** and **IoT-Gateways**, please update the firmware to at least version **2.0.2**.  \nThe firmware update can be obtained from [www.weidmueller.com](https://www.weidmueller.com).\n\nFor **u-create studio**, please update the **CodeMeter control center** software to at least version **7.60c**.  \nThe Codemeter control center is included in u-create studio and is installed on your computer in parallel.  \nThe Codemeter control center update can be obtained from the **WIBU-SYSTEMS** homepage.  \nLook for **'CodeMeter User Runtime für Windows'** on the WIBU website.\n\nFind below appropriate patched firmware versions for all affected products:\n\n| Product Number | Product Name                                      | Patched in Version |\n|----------------|---------------------------------------------------|---------------------|\n| 1334950000     | UC20-WL2000-AC (with u-OS)                        |  2.0.2             |\n| 1334990000     | UC20-WL2000-IOT (with u-OS)                       |  2.0.2             |\n| 2682620000     | IOT-GW30 (with u-OS)                              |  2.0.2             |\n| 2682630000     | IOT-GW30-4G-EU (with u-OS)                        |  2.0.2             |\n| 2660130000     | u-create studio with CodeMeter control center    |  7.60c             |",
        "title": "Remediation"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "psirt@weidmueller.com",
      "name": "Weidmueller Interface GmbH & Co. KG",
      "namespace": "https://www.weidmueller.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "VDE-2023-032: Weidmueller: WIBU Vulnerability in multiple Products - HTML",
        "url": "https://certvde.com/en/advisories/VDE-2023-032/"
      },
      {
        "category": "self",
        "summary": "VDE-2023-032: Weidmueller: WIBU Vulnerability in multiple Products - CSAF",
        "url": "https://weidmueller.csaf-tp.certvde.com/.well-known/csaf/white/2023/vde-2023-032.json"
      },
      {
        "category": "external",
        "summary": "Weidmueller PSIRT",
        "url": "https://www.weidmueller.com/int/solutions/solutions/industrial_security/index.jsp"
      },
      {
        "category": "external",
        "summary": "CERT@VDE Security Advisories for Weidmueller Interface GmbH & Co. KG",
        "url": "https://certvde.com/en/advisories/vendor/weidmueller/"
      }
    ],
    "title": "Weidmueller: WIBU Vulnerability in multiple Products",
    "tracking": {
      "aliases": [
        "VDE-2023-032"
      ],
      "current_release_date": "2025-05-22T13:03:10.000Z",
      "generator": {
        "date": "2025-05-05T12:10:06.840Z",
        "engine": {
          "name": "Secvisogram",
          "version": "2.5.24"
        }
      },
      "id": "VDE-2023-032",
      "initial_release_date": "2023-11-09T07:42:00.000Z",
      "revision_history": [
        {
          "date": "2023-11-09T07:42:00.000Z",
          "number": "1",
          "summary": "Initial revision."
        },
        {
          "date": "2025-05-22T13:03:10.000Z",
          "number": "2",
          "summary": "Fix: quotation mark"
        }
      ],
      "status": "final",
      "version": "2"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "branches": [
                  {
                    "category": "product_version",
                    "name": "2.0.0",
                    "product": {
                      "name": "IOT-GW30-4G-EU (with u-OS) 2.0.0",
                      "product_id": "CSAFPID-51001",
                      "product_identification_helper": {
                        "model_numbers": [
                          "2682630000"
                        ]
                      }
                    }
                  },
                  {
                    "category": "product_version",
                    "name": "2.0.1",
                    "product": {
                      "name": "IOT-GW30-4G-EU (with u-OS) 2.0.1",
                      "product_id": "CSAFPID-51002",
                      "product_identification_helper": {
                        "model_numbers": [
                          "2682630000"
                        ]
                      }
                    }
                  },
                  {
                    "category": "product_version",
                    "name": "2.0.2",
                    "product": {
                      "name": "IOT-GW30-4G-EU (with u-OS) 2.0.2",
                      "product_id": "CSAFPID-52001"
                    }
                  }
                ],
                "category": "product_name",
                "name": "IOT-GW30-4G-EU (with u-OS)"
              },
              {
                "branches": [
                  {
                    "category": "product_version",
                    "name": "2.0.0",
                    "product": {
                      "name": "IOT-GW30 (with u-OS) 2.0.0",
                      "product_id": "CSAFPID-51003",
                      "product_identification_helper": {
                        "model_numbers": [
                          "2682620000"
                        ]
                      }
                    }
                  },
                  {
                    "category": "product_version",
                    "name": "2.0.1",
                    "product": {
                      "name": "IOT-GW30 (with u-OS) 2.0.2",
                      "product_id": "CSAFPID-51004",
                      "product_identification_helper": {
                        "model_numbers": [
                          "2682620000"
                        ]
                      }
                    }
                  },
                  {
                    "category": "product_version",
                    "name": "2.0.2",
                    "product": {
                      "name": "IOT-GW30 (with u-OS) 2.0.2",
                      "product_id": "CSAFPID-52002"
                    }
                  }
                ],
                "category": "product_name",
                "name": "IOT-GW30 (with u-OS)"
              },
              {
                "branches": [
                  {
                    "category": "product_version",
                    "name": "2.0.0",
                    "product": {
                      "name": "UC20-WL2000-AC (with u-OS) 2.0.0",
                      "product_id": "CSAFPID-51005",
                      "product_identification_helper": {
                        "model_numbers": [
                          "1334950000"
                        ]
                      }
                    }
                  },
                  {
                    "category": "product_version",
                    "name": "2.0.1",
                    "product": {
                      "name": "UC20-WL2000-AC (with u-OS) 2.0.1",
                      "product_id": "CSAFPID-51006",
                      "product_identification_helper": {
                        "model_numbers": [
                          "1334950000"
                        ]
                      }
                    }
                  },
                  {
                    "category": "product_version",
                    "name": "2.0.2",
                    "product": {
                      "name": "UC20-WL2000-AC (with u-OS) 2.0.2",
                      "product_id": "CSAFPID-52003"
                    }
                  }
                ],
                "category": "product_name",
                "name": "UC20-WL2000-AC (with u-OS)"
              },
              {
                "branches": [
                  {
                    "category": "product_version",
                    "name": "2.0.0",
                    "product": {
                      "name": "UC20-WL2000-IOT (with u-OS) 2.0.0",
                      "product_id": "CSAFPID-51007",
                      "product_identification_helper": {
                        "model_numbers": [
                          "1334990000"
                        ]
                      }
                    }
                  },
                  {
                    "category": "product_version",
                    "name": "2.0.1",
                    "product": {
                      "name": "UC20-WL2000-IOT (with u-OS) 2.0.1",
                      "product_id": "CSAFPID-51008",
                      "product_identification_helper": {
                        "model_numbers": [
                          "1334990000"
                        ]
                      }
                    }
                  },
                  {
                    "category": "product_version",
                    "name": "2.0.2",
                    "product": {
                      "name": "UC20-WL2000-IOT (with u-OS) 2.0.2",
                      "product_id": "CSAFPID-52004"
                    }
                  }
                ],
                "category": "product_name",
                "name": "UC20-WL2000-IOT (with u-OS)"
              },
              {
                "branches": [
                  {
                    "category": "product_version_range",
                    "name": "<=4.2.4",
                    "product": {
                      "name": "u-create studio <= 4.2.4",
                      "product_id": "CSAFPID-51009",
                      "product_identification_helper": {
                        "model_numbers": [
                          "2660130000"
                        ]
                      }
                    }
                  },
                  {
                    "category": "product_version",
                    "name": "7.60c",
                    "product": {
                      "name": "u-create studio 7.60c",
                      "product_id": "CSAFPID-52005",
                      "product_identification_helper": {
                        "model_numbers": [
                          "2660130000"
                        ]
                      }
                    }
                  }
                ],
                "category": "product_name",
                "name": "u-create studio"
              }
            ],
            "category": "product_family",
            "name": "Software"
          }
        ],
        "category": "vendor",
        "name": "Weidmüller"
      }
    ],
    "product_groups": [
      {
        "group_id": "CSAFGID-0001",
        "product_ids": [
          "CSAFPID-51001",
          "CSAFPID-51002",
          "CSAFPID-51003",
          "CSAFPID-51004",
          "CSAFPID-51005",
          "CSAFPID-51006",
          "CSAFPID-51007",
          "CSAFPID-51008",
          "CSAFPID-51009"
        ],
        "summary": "Affected products."
      },
      {
        "group_id": "CSAFGID-0002",
        "product_ids": [
          "CSAFPID-52001",
          "CSAFPID-52002",
          "CSAFPID-52003",
          "CSAFPID-52004",
          "CSAFPID-52005"
        ],
        "summary": "Fixed products."
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2023-3935",
      "cwe": {
        "id": "CWE-787",
        "name": "Out-of-bounds Write"
      },
      "notes": [
        {
          "category": "description",
          "text": "A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system.",
          "title": "Vulnerability Description"
        }
      ],
      "product_status": {
        "fixed": [
          "CSAFPID-52001",
          "CSAFPID-52002",
          "CSAFPID-52003",
          "CSAFPID-52004",
          "CSAFPID-52005"
        ],
        "known_affected": [
          "CSAFPID-51001",
          "CSAFPID-51002",
          "CSAFPID-51003",
          "CSAFPID-51004",
          "CSAFPID-51005",
          "CSAFPID-51006",
          "CSAFPID-51007",
          "CSAFPID-51008",
          "CSAFPID-51009"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "u-create studio:\nDisabling the network server function within CodeMeter would mitigate the vulnerability. To disable this function\nplease refer to the following steps:\n\n1. Navigate to the CodeMeter WebAdmin Website\n2. Select option Settings > Server > Server access\n3. Choose option 'deactivate' in section 'network server'\n4. Click 'Apply' button on the bottom of the website",
          "group_ids": [
            "CSAFGID-0001"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "For the affected **u-control web Controllers** and **IoT-Gateways**, please update the firmware to at least version **2.0.2**.  \nThe firmware update can be obtained from [www.weidmueller.com](https://www.weidmueller.com).\n\nFor **u-create studio**, please update the **CodeMeter control center** software to at least version **7.60c**.  \nThe Codemeter control center is included in u-create studio and is installed on your computer in parallel.  \nThe Codemeter control center update can be obtained from the **WIBU-SYSTEMS** homepage.  \nLook for **'CodeMeter User Runtime für Windows'** on the WIBU website.\n\nFind below appropriate patched firmware versions for all affected products:\n\n| Product Number | Product Name                                      | Patched in Version |\n|----------------|---------------------------------------------------|---------------------|\n| 1334950000     | UC20-WL2000-AC (with u-OS)                        |  2.0.2             |\n| 1334990000     | UC20-WL2000-IOT (with u-OS)                       |  2.0.2             |\n| 2682620000     | IOT-GW30 (with u-OS)                              |  2.0.2             |\n| 2682630000     | IOT-GW30-4G-EU (with u-OS)                        |  2.0.2             |\n| 2660130000     | u-create studio with CodeMeter control center    |  7.60c             |",
          "group_ids": [
            "CSAFGID-0001"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "environmentalScore": 9.8,
            "environmentalSeverity": "CRITICAL",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "temporalScore": 9.8,
            "temporalSeverity": "CRITICAL",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-51001",
            "CSAFPID-51002",
            "CSAFPID-51003",
            "CSAFPID-51004",
            "CSAFPID-51005",
            "CSAFPID-51006",
            "CSAFPID-51007",
            "CSAFPID-51008",
            "CSAFPID-51009"
          ]
        }
      ],
      "title": "CVE-2023-3935"
    }
  ]
}
View JSON API Download JSON