vde-2025-011
MEDIUM CVSS 6.1 csaf_pepperlfuchsse
Description
A stored cross-site scripting vulnerability has been discovered in the profinet gateway LB8122A.1.EL. An attacker can write an HTML tag with up to 32 characters in the message field of a HART transmitter. The HTML tag is interpreted as HTML when the HART information is displayed in a webbrowser. If the HTML tag contains a link to a manipulated page, a user can be tricked into accessing this page. Furthermore, an attacker can access information about running processes via the SNMP protocol. Sending such SNMP read commands can also trigger a reboot.
Timeline
- Published
- 2025-05-26 10:00 UTC
- Last Modified
- 2025-08-27
CVSS Details
CVSS details not available.
Affected Products
No product information available.
References
No references available.
Linked Vulnerabilities
No linked vulnerabilities found.
{
"document": {
"acknowledgments": [
{
"organization": "CERT@VDE",
"summary": "coordination",
"urls": [
"https://certvde.com"
]
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"tlp": {
"label": "WHITE",
"url": "https://www.first.org/tlp/"
}
},
"lang": "en-GB",
"notes": [
{
"category": "summary",
"text": "A stored cross-site scripting vulnerability has been discovered in the profinet gateway LB8122A.1.EL. An attacker can write an HTML tag with up to 32 characters in the message field of a HART transmitter. The HTML tag is interpreted as HTML when the HART information is displayed in a webbrowser. If the HTML tag contains a link to a manipulated page, a user can be tricked into accessing this page.\nFurthermore, an attacker can access information about running processes via the SNMP protocol. Sending such SNMP read commands can also trigger a reboot.",
"title": "Summary"
},
{
"category": "description",
"text": "An unauthenticated attacker can use a stored HTML link in a HART transmitter to redirect a user to a manipulated website. From there, he can manipulate the user's device or environment.\nAn attacker can collect information via SNMP to launch attacks. Sending the read commands can trigger a reboot of the device.",
"title": "Impact"
},
{
"category": "description",
"text": "Please install the updated firmware V1.3.13.",
"title": "Remediation"
},
{
"category": "description",
"text": "The web server is switched off by default and can only be switched on via the gateway display. It is then active for 5 minutes and switches itself off again.\n - Ensure that only authorized personnel have access to the gateway.\n - Only use the gateway in an isolated network environment.",
"title": "Mitigation"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cert@pepperl-fuchs.com",
"name": "Pepperl+Fuchs SE",
"namespace": "https://www.pepperl-fuchs.com"
},
"references": [
{
"category": "external",
"summary": "Pepperl+Fuchs PSIRT",
"url": "https://pepperl-fuchs.com/cybersecurity"
},
{
"category": "external",
"summary": "CERT@VDE Security Advisories for Pepperl+Fuchs",
"url": "https://certvde.com/en/advisories/vendor/Pepperl+Fuchs"
},
{
"category": "self",
"summary": "VDE-2025-011: PEPPERL+FUCHS: Profinet Gateway LB8122A.1.EL – Device is affected by XSS vulnerability and information disclosure - HTML",
"url": "https://certvde.com/en/advisories/VDE-2025-011"
},
{
"category": "self",
"summary": "VDE-2025-011: PEPPERL+FUCHS: Profinet Gateway LB8122A.1.EL – Device is affected by XSS vulnerability and information disclosure - CSAF",
"url": "https://pepperl-fuchs.csaf-tp.certvde.com/.well-known/csaf/white/2025/vde-2025-011.json"
}
],
"title": "PEPPERL+FUCHS: Profinet Gateway LB8122A.1.EL – Device is affected by XSS vulnerability and information disclosure",
"tracking": {
"aliases": [
"VDE-2025-011"
],
"current_release_date": "2025-08-27T10:00:00.000Z",
"generator": {
"date": "2025-08-28T07:36:59.056Z",
"engine": {
"name": "Secvisogram",
"version": "2.5.34"
}
},
"id": "VDE-2025-011",
"initial_release_date": "2025-05-26T10:00:00.000Z",
"revision_history": [
{
"date": "2025-06-05T13:28:12.000Z",
"number": "1.0.0",
"summary": "Initial revision."
},
{
"date": "2025-08-27T10:00:00.000Z",
"number": "1.1.0",
"summary": "Update: CWE from CVE-2025-41654, Revision History"
}
],
"status": "final",
"version": "1.1.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_name",
"name": "LB8122A.1.EL",
"product": {
"name": "Profinet Gateway LB8122A.1.EL",
"product_id": "CSAFPID-11001",
"product_identification_helper": {
"model_numbers": [
"70120382",
"286519"
]
}
}
},
{
"category": "product_name",
"name": "FB8122A.1.EL",
"product": {
"name": "Profinet Gateway FB8122A.1.EL",
"product_id": "CSAFPID-11002",
"product_identification_helper": {
"model_numbers": [
"70138965",
"286522"
]
}
}
}
],
"category": "product_family",
"name": "Hardware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "<V1.3.13",
"product": {
"name": "Firmware <V1.3.13",
"product_id": "CSAFPID-21001"
}
},
{
"category": "product_version",
"name": "V1.3.13",
"product": {
"name": "Firmware V1.3.13",
"product_id": "CSAFPID-22001"
}
}
],
"category": "product_family",
"name": "Firmware"
}
],
"category": "vendor",
"name": "Pepperl+Fuchs"
}
],
"product_groups": [
{
"group_id": "CSAFGID-0001",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002"
],
"summary": "Affected products."
},
{
"group_id": "CSAFGID-0002",
"product_ids": [
"CSAFPID-32001",
"CSAFPID-32002"
],
"summary": "Fixed products."
}
],
"relationships": [
{
"category": "installed_on",
"full_product_name": {
"name": "Firmware <V1.3.13 installed on Profinet Gateway LB8122A.1.EL",
"product_id": "CSAFPID-31001"
},
"product_reference": "CSAFPID-21001",
"relates_to_product_reference": "CSAFPID-11001"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Firmware V1.3.13 installed on Profinet Gateway LB8122A.1.EL",
"product_id": "CSAFPID-32001"
},
"product_reference": "CSAFPID-22001",
"relates_to_product_reference": "CSAFPID-11001"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Firmware <V1.3.13 installed on Profinet Gateway FB8122A.1.EL",
"product_id": "CSAFPID-31002"
},
"product_reference": "CSAFPID-21001",
"relates_to_product_reference": "CSAFPID-11002"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Firmware V1.3.13 installed on Profinet Gateway FB8122A.1.EL",
"product_id": "CSAFPID-32002"
},
"product_reference": "CSAFPID-22001",
"relates_to_product_reference": "CSAFPID-11002"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2025-1985",
"cwe": {
"id": "CWE-79",
"name": "Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "Due to improper neutralization of input during web page generation (XSS) an unauthenticated remote attacker can inject HTML code into the Web-UI in the affected device. \n",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001",
"CSAFPID-32002"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Please install the updated firmware V1.3.13.",
"group_ids": [
"CSAFGID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"environmentalScore": 6.1,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"temporalScore": 6.1,
"temporalSeverity": "MEDIUM",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002"
]
}
],
"title": "CVE-2025-1985"
},
{
"cve": "CVE-2025-41654",
"cwe": {
"id": "CWE-306",
"name": "Missing Authentication for Critical Function"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An unauthenticated remote attacker can access information about running processes via the SNMP protocol. The amount of returned data can trigger a reboot by the watchdog. ",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001",
"CSAFPID-32002"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Please install the updated firmware V1.3.13.",
"product_ids": [
"CSAFPID-32001",
"CSAFPID-32002"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"environmentalScore": 8.2,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 8.2,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002"
]
}
],
"title": "CVE-2025-41654"
},
{
"cve": "CVE-2025-41655",
"cwe": {
"id": "CWE-306",
"name": "Missing Authentication for Critical Function"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An unauthenticated remote attacker can access a URL which causes the device to reboot.",
"title": "Vulnerability Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001",
"CSAFPID-32002"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Please install the updated firmware V1.3.13.",
"group_ids": [
"CSAFGID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002"
]
}
],
"title": "CVE-2025-41655"
}
]
}